Specifications

M1 Control RS-232 ASCII String Protocol Page 59 of 68 Rev. 1.79 July 16, 2009
Type Meaning Interpretation of Ext Info Field in Log Entries
1 Zone Number or Keypad
Number and F-Key
If 1-208, interpret as zone number.
If > 400, 401=KP1-F1, 402=KP1-F2, …
407=KP2-F1, … 496=KP16-F6.
2 User Number If control’s firmware is older than 4.4.0, the ext
info is 1-99; and 101=Installer, 102=ElkRP,
103=NoCode.
If control’s firmware is 4.4.0 or higher, the ext info
is 1-199; and 201=Installer, 202=ElkRP,
203=NoCode.
3 Expander Type For events of this type, ignore the “Area” field on
the log entry. It does not apply.
If the event is 1367 or the ext info is 0, this log
entry applies to the control. Otherwise:
1 = Keypad
2 = Input Expander
3 = Output Expander
4 = Reserved
5 = Serial Expander
4 EEPROM Address Address of a memory location in the EEPROM.
5 Voice message to play
when dialing phone #
0 = play default message (VM278)
209-323 = play VM209-VM323
Table 2 – How to interpret extended information