Technical Specifications

Elkay
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay
12-24H (Rev. 4/11)
I
MPORTANT!
I
NSTALLER PLEASE NOTE:
T
his water cooler has been designed and built to provide water to the user which has
n
ot been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes an
increase in the metal content of the water. This condition is avoidable by installing the
cooler using the proper materials as shown below.
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
T
he drain trap which is provided by the installer should also be plastic to completely
i
solate the cooler from the building plumbing system.
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3/8" O.D. TUBE
CONNECT
COLD WATER
SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3/8" O.D. TUBE
CONNECT
COLD WATER
SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT-OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE.
3" (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET TO ACCOMODATE 1-1/2" NOMINAL DRAIN. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/2 TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
FRONT VIEW SIDE VIEW
INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MINIMUM CLEARANCE FROM CABINET LOUVERS TO WALL.
REFRIGERATED UNITNON-REFRIGERATED UNIT
Two Station Wall Mount Water Coolers
Barrier-Free Access (Adult and Child)
NSF/ANSI 61 Compliant – Models EZTL8C,
EZSTL8C, EZTLDDC and EZSTLDDC
®
®
ROUGH-IN DIMENSIONS
RATED FOR INDOOR APPLICATIONS ONLY