Specification Sheet

Vandal-Resistant EZH2O
®
Bottle FillingStation
with Bi-Level Filtered Vandal-Resistant Cooler
Models LVRCTL8WS & LVRCTLDDWS
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been
altered by materials in the cooler waterway. The grounding of electrical equipment
such as telephone, computers, etc. to water lines is a common procedure. This
grounding may be in the building buy may also occur away from the building.
This grounding can cause electrical feedback into a water cooler creating an
electrolysis which results in a metallic taste or an increase in the metal content
of the water. This condition is avoidable by installing the cooler using the proper
materials as shown.
NOTICE:
This water cooler must be connected to the water supply using
a dielectric coupling. The cooler is furnished with a non-metallic
strainer which meets this requirement. The drain trap which is
provided by the installer should also be plastic to completely isolate
the cooler from the building plumbing system.
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (38mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: Installations Must Use Ground Fault Circuit Interrupter. (GFCI)
Printed in U.S.A.
© 2014 Elkay
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
13 7/8
352mm
18 3/4
476mm
20 1/8
511mm
25 1/8
638mm
11/16
18mm
3 1/2
89mm
4 1/2
114mm
6 1/4
159mm
5
127mm
2 1/2
63mm
10
254mm
20 3/8
518mm
2 9/16
65mm
7 1/4
185mm
3/4
18mm
4 1/2
116mm
F
A
E
D
B
F
E
18 1/2
470mm
1 1/4
32mm
1 1/4
32mm
7
178mm
16 5/16
414mm
18 1/16
459mm
1 3/8
34mm
5 3/4
146mm
5 3/4
146mm
1 3/8
35mm
37 1/2
953mm
6 1/2
165mm
O
5/16
8mm
HOLES (5)
1/4" x 1/2"
(6mm x 13mm)
OBROUND HOLES (5)
FINISHED FLOOR
FILTER
C
8
203mm
6 3/4
172mm
12 5/16
312mm
4 1/8
105mm
27
686mm
ADA
REQUIREMENT
31 13/16
808mm
RIM HEIGHT
33
838mm
ORIFICE
HEIGHT
39 9/16
1005mm
ORIFICE
HEIGHT
51 1/8
1299mm
HANGER
BRACKET
48
1220mm
2 5/8
66mm
1 1/2
37mm
18 11/16
474mm
FILTER
FINISHED FLOOR
7
178mm