3.1 Before You Begin
3.1.1 Site Requirements
You can guarantee the safe operation of the Dragonfly and Butterfly by ensuring that they are
installed in an appropriate environment.
Feature Value
Ambient operating temperature -40 °C to +70 °C (-40 °F to 160 °F)
Maximum relative humidity 95% non-condensing
Operating area atmosphere No flammable gases or vapors permitted in area
Note: Models for extended environmental conditions are available.
The Dragonfly and Butterfly dissipate their heat by convection. The maximum
ambient operating temperature of –40 °C to +70 °C (-40 °F to 160 °F) must not
be exceeded.
3.2 Unpacking the Amplifier
To unpack the Dragonfly and Butterfly:
Carefully remove the servo amplifier from the box and the Styrofoam.
1. Check the amplifier to ensure that there is no visible damage to the instrument. If any
damage has occurred, report immediately to the carrier that delivered your amplifier.
2. To ensure that the Dragonfly or Butterfly you have unpacked is the appropriate type for
your requirements, find the part number sticker on the side of the product:
The P/N gives the type designation
as follows:
Maximum DC
Operating Voltage
Continuous Current
(Amps)
BUT- X/YYY
Dragonfly/ Butterfly Installation Guide Installation
MAN-DRBUIG (Ver. 1.1)
3-1