Technical information

ECOMBI SYSTEM INSTALLATIONS
To enjoy the desired level of comfort and lower costs provided by the ECOMBI System, an appropriate sizing of the
room where it is to be installed is very important. The energy calculation for traditional storage systems must be
lowered by 15% to perform the appropriate calculations with the ECOMBI System.
ECOMBI
MODEL
ECO158 ECO208 ECO308 ECO408
Convector output* 230 V / 240 V W 450 / 490 600 / 653 900 / 980 1200 / 1307
Storage heater output* 230 V / 240 V W 975 / 1062 1300 / 1415 1950 / 2123 2600 / 2831
Charging (8h) kWh 7.8 10.4 15.6 20.8
Frecuency Hz
50-60 50-60 50-60 50-60
Length cm 55 66 89 111
Height cm 73 73 73 73
Depth cm 18 18 18 18
Weight kg 59 77 112 147
Num. of blocks 8kg - 8 12 16
Num. of blocks 12kg 4---
Units per pallet
mm
mm
20
10 10
8
- 1200x800
- 1200x1100
*Storage heater elements and convector element will never operate at the same time.
Technical features
Ź Silent performance.
Ź Temperature sensor with calibration option.
Ź Overheating protection at storage heating.
Ź Safety thermostat with manual reset.
Ź Class I insulation.
Ź Convector heating element made of Aluminium.
Ź Storage heating elements made of stainless steel.
Ź Michrotherm G 10mm insulation, vermiculite and
ecological bre.
Ź Front, side and real air isolating chambers.
Ź Storage core made of a specially designed material
for ECOMBI.
Ź Steel structure powder coated in epoxy RAL 9010.
Ź Robust plastic ttings.
Ź Easy to install on any kind of wall.
Ź Very intuitive keyboard with lock option.
Ź Compatible with two-period off peak electric tariff in
a single 24-hour interval.
Ź Daily and weekly programming.
Ź Deferred storage energy option.
Ź Storage, Combined storage, Convection, Frost
protection and Automatic ECOMBI operation modes
can be set up.
50