Installation guide

Quick Installation Guide
00825-0100-4648, Rev CC
February 2012
Rosemount 648 Wireless
13
European Certifications
I1 ATEX Intrinsic Safety
Certificate No.: Baseefa07ATEX0011X II 1G
Ex ia IIC T5 (T
a
= -60 °C to 40 °C)
Ex ia IIC T4 (T
a
= -60 °C to 70 °C)
IP66/IP67
Special Conditions for Safe Use (X)
1. The antenna may present a potential electrostatic ignition hazard and must not be
rubbed or cleaned with a dry cloth.
2. The enclosure is made of an aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion if
located in a zone 0 environment.
For use with Rosemount Power Module P/N 753-9220-0001 only.
Intrinsically Safe when installed per Rosemount drawing 00648-1020.
1180
Table 3. Sensor Parameters
International Certifications
I7 IECEx Intrinsic Safety
Certificate No.: IECEx BAS 07.0007X
Ex ia IIC T6 (T
amb
= -60 °C to 50 °C)
Ex ia IIC T5 (T
amb
= -60 °C to 75 °C)
IP66/IP67
Special Conditions for Safe Use (X)
1. The antenna may present a potential electrostatic ignition hazard and must not be
rubbed or cleaned with a dry cloth.
2. The enclosure is made of an aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion if
located in a zone 0 environment.
For use with Rosemount Power Module P/N 753-9220-0001 only.
Intrinsically Safe when installed per Rosemount drawing 00648-1020.
1180
Sensor
U
o
= 6.6 V
I
o
= 26 mA
P
o
= 42.6 mW
C
o
= 10.9 uF
L
o
= 500 mH
00825-0100-4648_CC.fm Page 13 Monday, February 13, 2012 12:48 PM