Installation guide

Quick Installation Guide
00825-0100-4648, Rev CC
February 2012
Rosemount 648 Wireless
2
© 2012 Rosemount Inc. All rights reserved. All marks property of owner.
IMPORTANT NOTICE
This installation guide provides basic guidelines for the Rosemount
®
648. It does not
provide instructions for detailed configuration, diagnostics, maintenance, service,
troubleshooting, or installations. Refer to the Rosemount 648 Reference Manual
(Document No. 00809-0100-4648) for more instruction. The manual and this QIG are also
available electronically on www.rosemount.com.
WARNING
Explosions could result in death or serious injury:
Installation of this transmitter in an explosive environment must be in accordance with the
appropriate local, national, and international standards, codes, and practices. Please
review the Product Certifications section for any restrictions associated with a safe
installation.
Before connecting a Rosemount Field Communicator in an explosive atmosphere,
ensure the instruments are installed in accordance with intrinsically safe or
non-incendive field wiring practices. Electrical shock can result in death or serious
injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads
can cause electrical shock. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions. This device may not cause harmful
interference. This device must accept any interference received, including
interference that may cause undesired operation. This device must be installed to
ensure a minimum antenna separation distance of 20 cm from all persons.
The Power Module may be replaced in a hazardous area. The Power Module has
surface resistivity greater than one gigaohm and must be properly installed in the
wireless device enclosure. Care must be taken during transportation to and from the
point of installation to prevent electrostatic charge build-up.
IMPORTANT NOTICE
Shipping considerations for wireless products:
The unit was shipped to you without the Power Module installed. Please remove the
Power Module prior to shipping the unit.
Each Power Module contains two “C” size primary lithium batteries. Primary lithium
batteries are regulated in transportation by the U.S. Department of Transportation, and
are also covered by IATA (International Air Transport Association), ICAO (International
Civil Aviation Organization), and ARD (European Ground Transportation of Dangerous
Goods). It is the responsibility of the shipper to ensure compliance with these or any other
local requirements. Please consult current regulations and requirements before shipping.
Emerson Process Management
Rosemount Division
8200 Market Boulevard
Chanhassen, MN USA 55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 906-8889
Rosemount Temperature GmbH
Frankenstrasse 21
63791 Karlstein
Germany
T 49 (6188) 992 0
F 49 (6188) 992 112
Emerson Process Management
Asia Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947 / (65) 6777 0743
Enquiries@AP.EmersonProcess.com
00825-0100-4648_CC.fm Page 2 Monday, February 13, 2012 12:48 PM