Instructions / Assembly

5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: 52-ANT
Turning off wall switch is not sufficient. To avoid
p
ossible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
3.1
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan mounting plate on the outlet box.
CEILING
COVER
42" MOTOR
LEADS
Figure 1
3. Ceiling Fan Assembly
3.2
Pass the three 42" motor leads through the opening in
the ceiling cover.
Be sure the cover is oriented correctly (Figure 1).
HANGER BALL/
4.5" DOWNROD
ASSEMBLY
42" MOTOR
LEADS
Figure 2
3.3
Separate, untwist and unkink the three 42" motor
leads.
Route the 42" motor leads through the hanger
ball/downrod assembly (Figure 2).