CAST IRON DIRECT VENT FIREPLACE INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL MODEL CIDV-30-7

Page 2 R-5086
Specifications
Model CIDV-30
Input BTU/HR (KW/H) Max (LP/NAT) 30,000 (8.7)
BTU/HR (KW/H) Min. LP 22,000 (6.4)
BTU/HR (KW/H) Min. Nat. 19,500 (5.7)
Height 27 3/4" (70.5cm)
Width 25 1/2" (64.8cm)
Depth 23" (58.4cm)
Gas Inlet (Pipe) 1/2" (13mm)
Floor to top of collar on vertical 27 5/8" (70.2cm)
position of Vent Elbow
Floor to center of collar on horizontal 24 3/32" (61.2cm)
position of Vent Elbow
Floor to Center of 90° elbow with a 55 1/2" (141cm)
24" length of pipe (see Figure 5)
Stove Casting (Must be ordered with Firebox.)
CIFB-1 Flat Black
CIPB-1 Porcelain Black
CIPG-1 Porcelain Green
CIPS-1 Porcelain Sand
CIPN-1 Porcelain Navy
CIPR-1 Porcelain Red
Accessories
GWSG-T 750 Millivolt Wall Thermostat
DVKH-1 Direct Vent Kit for Horizontal Run
(Includes DVKA-1 Adapter)
DVKV-1 Direct Vent Kit for Vertical Run
(Includes DVKA-1 Adapter)
DVKA-1 Direct Vent Kit Adapter
FRBC-1 Battery Operated Remote Control
FRBTC-1 Battery Operated Remote Control w/Thermostat
FREC-1 Electric Remote Control
FWS-1 Wall Switch
CIB-2 Automatic Blower
Stone Inlay Replaces Standard Grille Top
CII-2 Stone Inlay Empress Green
CII-3 Stone Inlay Hunan Jade
CII-4 Stone Inlay Gray Botticino
CII-5 Stone Inlay Azul
CII-6 Stone Inlay Salome
CII-7 Stone Inlay Black Swan
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card
supplied with appliance.
3. Installer should show owner how to start and operate appliance
and thermostat.
WARNING: Any change to this appliance or its control can
be dangerous. This is a heating appliance and any panel,
door or guard removed for servicing an appliance must be
replaced prior to operating the appliance.
General Information
This appliance is design certified in accordance with American National
Standard/CSA Standard ANSI Z21.88-1998/CSA 2.33-M98 by the
American Gas Association and Canadian Gas Association as a Direct
Vent Fireplace and should be installed according to these instructions.
The efficiency rating of this appliance is a product thermal efficiency
rating determined under continuous operating conditions and was
determined independently of any installed system.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown on
the rating plate is the responsibility of the person and company
making the change.
Notice During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
WARNING: Do not operate appliance with the glass front
removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualified service person.
WARNING: If not installed, operated and maintained in
accordance with the manufacturer's instructions, this product
could expose you to substances in fuel or from fuel combustion
which can cause death or serious illness.
Appliance must not be connected to a chimney flue that is servicing a
separate solid-fuel burning appliance.
Attention: All vent runs must have a minimum VERTICAL rise of
two feet. If the vent run is directly behind the appliance, you must
attach Simpson Dura-Vent 36" snorkel, part number SD-981 on the
exterior of the building. See Venting Requirements, page 11.
Due to high temperatures the appliance should be located out
of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns or
clothing ignition.
Young children should be carefully supervised when they are
in the same room as the appliance.
Clothing or other flammable material should not be placed on
or near the appliance.
Surveiller les enfants. Garder les vêtements, les meubles, l'essence
ou autres liquides à vapeur inflammables lin de l'appareil.
Any safety screen or guard removed for servicing an appliance
must be replaced prior to operating the appliance.
The glass front or any part removed for servicing the appliance
must be replaced prior to operating the appliance. Work should
be done by a qualified service person
Keep burner and control compartment clean.
Vent cap hot while furnace is in operation.
Installation and repair should be done by a QUALIFIED
SERVICE PERSON. The appliance should be inspected be-
fore use and at least annually by a qualified service person.
More frequent cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is imperative that
control compartments, burners and circulating air passage-
ways of the appliance be kept clean.
S'assurer que le brûleur et le compartiment des commandes sont
propres. Voir les instructions d'installation et d'utilisation qui
accompagnent l'appareil.
DO NOT put anything around the furnace that will obstruct
the flow of combustion and ventilation air.
DO keep the appliance area clear and free from combustible
material, gasoline and other flammable vapors and liquids.
DO examine venting system periodically and replace dam-
aged parts.
CAUTION: The glass used in your heater is a special high
temperature ceramic glass. If the glass is cracked or damaged in
any way, it should be replaced only with a complete glass frame
assembly from Empire. See parts list on Page 26 for ordering.
DO make a periodic visual check of pilot and burner. Clean
and replace damaged parts.
DO NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Ne pas se servir de cet appareil s'il a été plongé dans l'eau,
complètement ou en partie. Appeler un technicien qualifié pour
inspecter l'appareil et remplacer toute partie du système de
contrôle et toute commande qui ont été plongés dans l'eau.
Under no circumstances should any solid fuels (wood, coal, paper
or cardboard, etc.) be used in this appliance.
THIS IS A HEATING APPLIANCE