Owner`s manual

30067-0-0512 Page 13
Service and Maintenance
Although most service should be conducted by a qualied service
person, there are several things that can be checked to ensure
safe and comfortable operation.
Keep the area surrounding the replace free from any types of
combustible materials. The lter should be checked and cleaned
on a monthly basis. All other maintenance should be conducted
by a qualied service person.
CirculatingAirBlower
The circulating air blower should be checked and cleaned annu-
ally by a qualied service person to ensure that your appliance is
operating efciently. Any dirt or lint can affect the operation of the
blower.
Heat Exchanger
The heat exchanger is located on the backside of the replace.
The heat exchanger should be inspected and cleaned annually by
a qualied service person.
Filter
The lter is located on the inside of the lower louver panel on
Bay Window Models and on Fireplace models equipped with FIK,
FFK or FWK Surrounds. On Fireplace models equipped with the
FHK louverless surround, the lter is located on the inside bottom
ange of the surround (FHK Surrounds).
To clean the lter on replaces equipped with the lower louver
panel, remove the panel and disengage the lter rod from its re-
taining holes.
For Fireplace Models equipped with louverless FHK surrounds,
the entire surround must be removed from the replace. This is
accomplished by lifting and removing the surround from the sup-
port bracket hooks. Remove the lter retainers and lters from the
inside bottom ange by removing the screw holding the lter re-
tainer in place.
The lters may be rinsed with water or blown clean with com-
pressed air. Allow the lters to dry completely before reinstalling
them.
RECOMMENDED MAINTENANCE
MAINTENANCE ITEM
FREQUENCYOFMAINTENANCE
MONTHLY BY
HOMEOWNER
ANNUALLY BY
SERVICE PERSON
Verify the area is free from combustible materials. X X
Verify the combustion and ventilation air is not restricted. X
Verify the ue and inlet pipes do not have any cracks or holes. X
Verify burner ame. X
Clean the blower compartment X
Clean the burner. X
Verify the condensate system is clean and leak free. X
Clean the lter X X
Clean the glass X X
Clean the heat exchanger X