Owner`s manual

28365-2-0811Page 14
Note: For nishing to top of replace, refer to Figure 14.
Figure 13
Attention: Add 3-3/4" to “A” dimensions when using a ush mantel
base.
Attention: If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
other than wood ooring, it shall be installed on a metal or wood
panel extending the full width and depth of the appliance. The
vertical dimension in Figure 13 must be adjusted when a metal or
wood panel is placed beneath the appliance.
Finishing (Figures 14 and 15)
Finish the walls with the material of your choice. Figure 4 on page 9
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the replace.
Only non-combustible materials may be used to cover the black
replace front.
Caution: If the joints between the nished wall and the replace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the replace surround.
Flush Mount Mantel Installation (Figure 12)
The replace must extend 3/4" beyond nished wall surface when
using a ush mount mantel. Refer to Figure 12 to locate nailing
anges on replace sides. Mark and drill two (2) 1/8" holes into
replace side to mount each nailing ange. Use eight (8) 1/2" hex-
head screws supplied in hardware package to attach nailing anges
to replace sides.
Figure 12
Attention: When replace is installed in optional full cabinet mantel
or corner mantel the (4) four nailing anges shown in Figure 12 will
not be installed on the side of outer casing. The replace will be
attached to the full cabinet mantel or corner mantel with the (2) two
nailing anges located on the top of the outer casing assembly.
Framing (Figure 13)
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the replace standoffs. Refer to Figure 13 for minimum
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
INSTALLATION (continued)
Framing dimension "A" includes a three inch clearance for
     


DVCD32 DVCD36 DVCD42
"A" 35 3/4"
(908 mm)
35 3/4"
(908 mm)
37 3/4"
(959 mm)
"B" 34 3/8"
(873 mm)
37 3/8"
(949 mm)
43 3/8"
(1102 mm)
"C" 16 3/8"
(416 mm)
16 3/8"
(416 mm)
16 3/8"
(416 mm)
      
or modify the air inlet/outlet louvers in any manner.
Provide adequate clearances around air openings into the

NAIL OR OTHER SUITABLE FASTENER