Owner`s manual
28365-2-0811Page 14
Note: For nishing to top of replace, refer to Figure 14.
Figure 13
Attention: Add 3-3/4" to “A” dimensions when using a ush mantel
base.
Attention: If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
other than wood ooring, it shall be installed on a metal or wood
panel extending the full width and depth of the appliance. The
vertical dimension in Figure 13 must be adjusted when a metal or
wood panel is placed beneath the appliance.
Finishing (Figures 14 and 15)
Finish the walls with the material of your choice. Figure 4 on page 9
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the replace.
Only non-combustible materials may be used to cover the black
replace front.
Caution: If the joints between the nished wall and the replace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the replace surround.
Flush Mount Mantel Installation (Figure 12)
The replace must extend 3/4" beyond nished wall surface when
using a ush mount mantel. Refer to Figure 12 to locate nailing
anges on replace sides. Mark and drill two (2) 1/8" holes into
replace side to mount each nailing ange. Use eight (8) 1/2" hex-
head screws supplied in hardware package to attach nailing anges
to replace sides.
Figure 12
Attention: When replace is installed in optional full cabinet mantel
or corner mantel the (4) four nailing anges shown in Figure 12 will
not be installed on the side of outer casing. The replace will be
attached to the full cabinet mantel or corner mantel with the (2) two
nailing anges located on the top of the outer casing assembly.
Framing (Figure 13)
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the replace standoffs. Refer to Figure 13 for minimum
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
INSTALLATION (continued)
Framing dimension "A" includes a three inch clearance for
DVCD32 DVCD36 DVCD42
"A" 35 3/4"
(908 mm)
35 3/4"
(908 mm)
37 3/4"
(959 mm)
"B" 34 3/8"
(873 mm)
37 3/8"
(949 mm)
43 3/8"
(1102 mm)
"C" 16 3/8"
(416 mm)
16 3/8"
(416 mm)
16 3/8"
(416 mm)
or modify the air inlet/outlet louvers in any manner.
Provide adequate clearances around air openings into the
NAIL OR OTHER SUITABLE FASTENER