Owner`s manual

28365-2-0811Page 38
The OWNER should carefully read and follow these operating
instructions at all times. Lower the door assembly to view the gas
controls for the replace.
Initial Lighting
Upon completing the gas line or turning the gas valve on after it has
been in the “OFF” position, a small amount of air will be in the lines.
When rst lighting the replace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is complete,
the replace will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging
if the gas valve is not turned to “OFF.”
Pilot Flame (Figure 61)
The thermopile/thermocouple (standing pilot) tips should be covered
with ame.
Figure 61
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning pilot.
The pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermopile produces millivolts (electrical
current) which energizes the magnet in the gas valve. After 30
seconds to 1 minute time period you can release the gas control
knob and the pilot will stay ON. Allow your pilot ame to operate an
additional one (1) to two (2) minutes before you turn the gas control
knob from the PILOT position to the ON position. This time period
allows the millivolts (electrical current) to build-up to a sufcient
level allowing the gas control to operate properly.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for
standing pilot controls found in this manual and on labels found
in control compartment behind the door assembly.



least once every second.
2. During the operating season, leave the control valve knob in
the “ON” position. This will allow the pilot ame to remain lit.
Turn the burner ame on or off with the replace REMOTE/
OFF/ON switch, wall switch or remote controls.
NOTE: The gas control valve allows you to increase or decrease the
height of the main burner ame. The control valve has a pressure
regulator with a knob as shown in Figure 60. Rotate the knob
clockwise to “HI” to increase the ame height and counterclockwise
to “LO” to decrease the ame height.
3. When the operating season is over, turn the REMOTE/OFF/ON
switch to “OFF” and the control valve to “OFF”. The system,
including the pilot light, will be shut down.
Figure 60
CONTROL KNOB
HI/LO REGULATOR
OPERATING INSTRUCTIONS