Owner`s manual

28365-2-0811 Page 43
LED LIGHT
LED LUMIÈRE
BLACK NOIR
GREEN VERT
WHITE BLANC
RED ROUGE
BLACK NOIR
GAS VALVE
VALVEDEGAZ
(OPTIONAL) WALL SWITCH
INTERRUPTEURMURAL
(FACULTATIVE)
120 VAC LINE
120 VACRTN
JUNCTIONBOX
JONCTIONBOÎTE
SPARKIGNITOR
ÉTINCELLE ALLUMER
(OPTIONAL) REMOTECONTROL
RECEIVER 120V
(FACULATIVE) CONTROLEE
DISTANCE DU RECEPTEUR
MAIN VALVE RETURN 1
12
13
GROUND 2
120V AC RETURN 4
120V AC HOT 6
MAIN VALVE HOT 8
CONTROL MODULE
AUTORITÉ MODULE
OR THERMOSTAT
LED CODES
Steady ON Normal operation, power ON to control
2 Flashes 3 unsuccessful ignition trials
3 Flashes Main burner ame failed 4 times during a single heating cycle
4 Flashes Interrupt power for 5 seconds to reset control
Steady Flash Flame detected out of sequence
Electric (120 volt) Operated Remote Control (FREC)
1. Disconnect 3-prong power cord from receptacle.
2. Remove wire from 120 VAC hot terminal on control module.
3. Connect female terminal from receiver onto 120 VAC hot
terminal on control module.
4. Connect remaining wire from remote control (male terminal)
to (female terminal) on power cord removed from control
module (step 2).
5. Insert electric remote control power cord plug into the
junction box on the right side of replace.
6. Connect 3-prong plug into receptacle. See wiring diagram on
page 55.
Figure 63
DIRECT IGNITION WIRING DIAGRAM
OPTIONAL REMOTE CONTROL