Owner`s manual

26557-0-0110Page 4
Sidewall Clearances:Theclearancefromtheinsideofthereboxtoperpendicularcombustiblesidewallshouldnotbelessthan13/4".
See Figures 1a and 1b.
Combustible material clearance from front of rebox: 36" minimum
Firebox Side and Back Clearances:Thereboxoutercasingside(s)requireaminimum1/2"clearancetocombustibles.
Top Framing and Finishing:Combustibleframingmayrestontopofstandoffs.Combustiblenishingmaterialsmayextendtothetop
standoff screws on the front edge of the top outer wrap. See Figures 2a and 2b.
CLEARANCES
FIREBOX
STAND OFF
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.
Figure 1a - See Through Firebox Clearances
Figure 2a - Louvered Models
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD)
1 3/4MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD)
1 3/4MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 1b - Peninsula Firebox Clearances
Figure 2b - Flush Models
FIREBOX
STAND OFF
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.