Owner`s manual

26557-0-0110 Page 5
Figure 3a - Mantel Clearances with Standard Hood
Figure 3b - Mantel Clearances with Optional Extended Hood
MANTEL
STANDARD
HOOD
17 ½”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
4½
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
8”
6½
5”
3½
1½
0”
6½
9”
11
13”
15”
MANTEL
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
8”
MIN.
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
22”
8”
20”
6½
18”
5”
16”
3½
14 ½”
2½
24 ½”
0”
FIREBOX
FACE
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
CLEARANCES
Ceiling Clearances:Theceilingheightshouldnotbelessthan42"fromthetopofthehood.See Figures 3a and 3b.
Mantel Clearances: Ventfreereboxmodelsmustusethehoodsuppliedwiththerebox,oroneoftheoptionalhoodkitsavailablefor
each model. If a combustible mantel is installed, it must meet the clearance requirements detailed below.
Grate Clearance: Theminimumclearancebetweenthefrontlegsofthegrateandthefrontedgesofthereboxis11/2".