Owner`s manual
26557-0-0110 Page 9
Thereboxisdesignedtoacceptagaslineforanapprovedvent-
freegaslogset.Havethelineinstalledbyaqualiedserviceperson
in accordance with all building codes. Consult local building codes
to properly size the gas supply line leading to the connection of the
logsetburner.ThestateofMassachusettsrequiresthataexible
appliance connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of
the firebox. See Figure 10. Carefully remove the indented
knockout in the ceramic brick panel using a drill or utility knife.
See Figure 11.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of
gas supply, DO NOT INSTALL. Contact your dealer for proper
model.
AlwaysuseanexternalregulatorforallLPreboxestoreducethe
supplytankpressuretoamaximumof14"w.c.Thisisinaddition
totheregulatorttedtothelogset.
WA R N I N G : CO N N E C T I O N D I R E C T LY T O A N
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
InstallonlyaANSIZ21.11.2vent-freelogsetintothisrebox.
Figure 10
Extended Hoods
Ifyournon-combustiblefacingmaterialisover1"inthicknessandwillbeusedtonishthisrebox,extendedhoodsareavailablethat
willextendout2"fartherintotheroom.Extendedhoodsarenotavailableforthepeninsulaopenends.Contactyourlocaldealerfor
details.
Finishing
Alljoints(top,bottomandsides),wherethewallordecorativefacingmaterialmeetsthereboxsurroundshouldbesealedwithanon-
combustible material.
Hearthextensionsarerequiredforthesereboxes.
Flush panels, louvers, and decorative louver panels are interchangeable, and may be mixed and matched as desired (i.e. Flush panel on
bottom with louvered panel at top, or vice versa).
Extended Hoods
VB4H36BL Standard Black (1 each)
VB4H36BR Polished Brass (1 each)
VB4H36SS Stainless Steel (1 each)
VB4H36HP Hammered Pewter (1 each)
Figure 11
INSTALLING HOOD (continued)
GAS LINE CONNECTION
GAS LINE
ACCESS
HOLES