Owner`s manual

26284-3-0813 Page 17
1. If applicable, turn OFF gas supply to vented decorative log
set.
2. If applicable, remove gas supply line from vented decorative
log set.
3.  remove Natural gas inlet regulator
from burner assembly.
3.      remove regulator cap and blue
conversion screw from HI-LO knob on gas valve.
4.     only, install Propane (LP) gas inlet
regulator  onto burner assembly.
4.     only, install Propane (LP) gas 
 into HI-LO knob on gas valve. Assure that
conversion screw is nger tight (refer to Honeywell conversion
instructions which are included in conversion kit). Install new
regulator cap over pink conversion screw.
5. Remove Natural gas main burner orice from orice tting.
Save the Natural gas main burner orice from the appliance
for future use.
Attention: Use appropriate main burner orice for 
input or REDUCED input.
6. Install Propane (LP) gas main burner orice into orice tting
for  input.
install one Propane (LP) gas main
burner orice  for 65,000 BTUH input.
 install one Propane (LP) gas main
burner orice  for 75,000 BTUH input.
 install one Propane (LP) gas main
burner orice  for 75,000 BTUH input.
6. Install Propane (LP) gas main burner orice into orice tting
for REDUCED input.
 install one Propane (LP) gas main
burner orice  for 40,000 BTUH input.
 install one Propane (LP) gas main
burner orice  for 50,000 BTUH input.
 install one Propane (LP) gas main
burner orice  for 60,000 BTUH input.
7. Remove pilot tubing from pilot burner.
8. Remove Natural gas pilot orice from pilot burner. Save the
Natural gas pilot orice removed from the appliance for future
use.
9. Insert Propane (LP) gas pilot orice   into pilot
burner.
10. Attach pilot tubing into pilot burner.
11. Connect gas supply line to vented decorative log set.
12. Attach R-1322, conversion label and R-1321, gas conversion
label to the 4 3/4" x 7 1/4" metal plate supplied in conversion
kit. Attach 4 3/4" x 7 1/4" metal plate to metal chain which is
attached to base assembly.
13. 
a. To check the inlet pressure to the gas valve, a 1/8"
(3mm) N.P.T. plugged tapping, accessible for test gauge
connection, must be placed immediately upstream of the
gas supply connection to the appliance.
b. The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
c. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
 If one of the above procedures results in
pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on
the appliance gas valve, it will result in a hazardous
condition.
14. Turn on Propane (LP) gas supply to vented decorative log
set.
15. All gas connections must be checked for gas leaks by the
person (qualied agency) making the gas conversion. This
should be done with a soap solution watching for bubbles on
all exposed connections, and if unexposed, a pressure test
must be done.
16. Check the appropriate manifold pressure for the vented
decorative log set according to  on Page 8 in this
manual.
17. Check pilot burner ame pattern according to 
 on Page 12 in this manual.
18. Check main burner ame pattern according to 
 on Page 12 in this manual.
19. Gas conversion is completed.
Attention: The Propane (LP) gas conversion kit must be ordered
from Empire Comfort Systems, Inc.
