Owner`s manual

26284-3-0813 Page 5

1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner ll out and mail warranty card supplied
with the replace.
3. Installer should show owner how to start and operate the
replace.
WARNING
ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN
BE DANGEROUS.
-




Burner Pan Assembly
"M" model includes manual gas valve, regulator and safety
pilot.
"R" model includes millivolt valve and safety thermopile
generator and on/off switch. A remote control or wall switch
accessory is available as an option for this model.
1 Bag of Glowing Embers (Rock Wool)
1 Damper Clamp
2 Bags Decorative Rock
Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of a vented
decorative gas log set in a solid-fuel burning replace.
This appliance is only for use with the type of gas indicated on the
rating plate.
This series is design certied in accordance with American National Standard/CSA Standard Z21.60 and CGA 2.26, respectively, by the
Canadian Standards Association as a Vented Decorative Appliance and should be installed according to these instructions.



All correspondence should refer to complete Model Number, Serial Number and type of gas.
Notice: During initial use of the logs and branches you will detect an odor as the logs and branches are cured.
INTRODUCTION


Model Input
Btuh
** Reduced
Input
BTUH
Minimum
Front
Width
Depth Height
VSM-18* 65,000 40,000 32" 15" 22"
VSM-24* 75,000 50,000 34" 15" 22"
VSM-30* 75,000 60,000 38" 15" 22"
VSR-18† 65,000 40,000 28" 15" 22"
VSR-24† 75,000 50,000 30" 15" 22"
VSR-30† 75,000 60,000 34" 15" 22"
Model Input
KW/H
**Reduced
Input BTUH
Minimum
Front
Width (cm)
Depth
(cm)
Height
(cm)
VSM-18* 19.0 11.7 81.3 38.1 55.8
VSM-24* 21.9 14.6 86.4 38.1 55.8
VSM-30* 21.9 17.5 96.5 38.1 55.8
VSR-18† 19.0 11.7 71.1 38.1 55.8
VSR-24† 21.9 14.6 76.2 38.1 55.8
VSR-30† 21.9 17.5 86.4 38.1 55.8
* M Denotes manual gas valve
† R Denotes millivolt gas valve
** Attention: An additional main burner orice is provided
in instruction package envelope to reduce the input of the burner
assembly.
Gas Inlet VSM Models 3/8" (9.5mm)
Gas Inlet VSR Models 3/8" (9.5mm)

Embers Kit EK-1

Battery Operated Remote Control FRBC
Electric Remote FREC
Wall Switch FWS