Owner`s manual

26284-3-0813Page 6

Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be per-
formed only by a qualied agency. The term "qualied agency" means
any individual, rm, corporation or company which either in person
or through a representative is engaged in and is responsible for (a)
the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
   The installation must be made
by a licensed plumber or gas tter in the Commonwealth of
Massachusetts.
The installation and the provisions for combustion and ventilation
air must conform with the National Fuel Gas Code, ANSI Z223.1/
NFPA54* Canadian Installation Code CAN/CGA B149.
*Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10018.
High Altitude Installation
When installing this unit at an elevation above 2000 feet (in the
United States) it may be necessary to decrease the input rating by
changing the existing burner orice to a smaller size. Generally,
input should be reduced 4 percent for each 1000 feet above sea
level. However, if the heating value of the gas has been reduced,
this general rule may not apply. Check with local gas utility for proper
orice size identication.
For Canadian high altitude applications, this appliance is suitable for
installation at elevations between 0 feet (0m) and 4,500 (1,370m)
without change.
When installing this unit at an elevation above 4500 feet (1,370m)
(in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper
orice for location.
Turn off gas supply to replace or rebox.
Have the replace oor and chimney professionally cleaned to
remove ashes, soot, creosote or other obstructions.
Have this cleaning performed annually after installation.
Seal any fresh air vents or ash clean-out doors located on oor
or wall of replace. If not, drafting may cause pilot
outage or sooting. Use a heat-resistant sealant. Do not seal
chimney ue damper.

Remove all ashes or other debris from the replace. If the replace
is equipped with an ash dump be sure to seal the door with furnace
cement or high temperature silicone. Be sure to check the damper for
proper operation and verify that the ue passageway is open. Attach
damper clamp to the vent damper and tighten hold down bolt.
Place the clamp over the lip of the damper and tighten the hold
down bolt until the clamp is securely attached to the damper. This
will prevent the damper from accidentally closing.
State of Massachusetts requirement for installation of vented
decorative appliance in a vented replace is the following:
In the Commonwealth of Massachusetts vent free products are
not approved.
A vented decorative gas appliance must be installed in a vented
replace only in the state of Massachusetts. The vent damper
must be removed or welded permanently open.


FIREPLACE PREPARATION