INTERMITTENT PILOT OPERATING INSTRUCTIONS
Thermostats are not approved on vented decorative appli-
ances.
Label all wires prior to disconnection when servicing controls. Wir-
ing errors can cause improper and dangerous operation. Verify
proper operation after servicing.
The 7 series Loft Fireplace operate with a GV60 battery-powered
electronic remote ignition and control system.
Prior to operation of the 7 series Loft Fireplace, install (4) AA bat-
teries into the Remote Receiver module, and (1) 9-volt battery into
the hand held remote.
The remote control and receiver should be programmed together
from the factory. All settings for time and temperature control must
be set up by the user as desired.
Figure 19
MANUAL KNOB
GAS INLET
(3/8 NPT)
INLET PRESSURE TAP
OUTLET PRESSURE TAP
MAIN VALVE KNOB
REMOTE RECEIVER MODULE