• Continuing beeps conrm the ignition is in process.
• Once pilot ignition is conrmed, there is main gas ow.
• After the ignition the remote will go automatically into tem-
perature control mode.
Caution: If the pilot does not stay lit after several tries, turn the
main valve knob to OFF and follow the instructions "Turn Off Gas
to Appliance" (See page 26).
Figure 21 Figure 22
TO TURN OFF APPLIANCE
Press OFF button on remote handset.
Notice: Press (small ame) to turn main gas to pilot gas.
ADJUSTMENT - FLAME HEIGHT
Standard, Display, Timer/Thermostat RF Remote Handsets
• In standby mode: Press (large ame) to increase ame
height.
• Press (small ame) to decrease ame height or to set ap-
pliance at pilot ame.
• For ne adjustment tap the large/small ames.
Quick Flame Adjust - Display, Timer/Thermostat RF Remote
Handset
• If (large ame) or (small ame) are pressed for 0.5 sec-
onds, the motor will turn the valve to high re or pilot ame.
Caution: If the appliance will not operate, follow the instructions
"TURN OFF GAS TO APPLIANCE" (See page 26).
SETTING °C/24 HOUR OR °F/12 HOUR CLOCK
Display, Timer/Thermostat RF Remote Handsets
• Press OFF and (small ame) until display changes from
Fahrenheit/12 hour clock to Celsius/24 hour clock and vice
versa.
AUTOMATIC OPERATION
WARNING
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
SETTING THE ELECTRONICS CODE
Notice: The remote control and receiver are pre-programmed at
the factory. However, if for some reason they do not communicate
to each other, follow these steps to re-program.
Radio Frequency Remote
A code is selected automatically for all Mertik Maxitrol electronics
from among 65,000 random codes available. The receiver has to
learn the code of the handset:
• Press and hold the receiver's reset button (see gure 18) until
you hear two (2) beeps. After the second, longer beep, re-
lease the reset button.
• Within the subsequent 20 seconds press the (small ame)
button on the remote handset until you hear an additional long
beep conrming the code is set.
Notice: This is a one time setting only, and is not required when
changing the batteries in the remote or receiver.
Figure 20
TO TURN ON APPLIANCE
WARNING
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
• Turn MANUAL knob to the ON, full counterclockwise
position (See Figure 21).
• Place ON/OFF switch (if equipped) in (ON position).
Standard, Display, Timer/Thermostat RF Remote Handset
• Simultaneously press and hold the OFF and (large ame)
buttons until a short beep conrms the start sequence has
begun; release buttons.
INTERMITTENT PILOT REMOTE ELECTRONIC IGNITION AND
CONTROL SYSTEM