Owner`s manual

27407-4-1010 Page 25
Notice: The display shows the set temperature every 30 sec-
onds.
SETTING THE TEMPERATURE
Select either the
TEMP
MODE or the
TEMP
MODE by
briey pressing the SET button.
Hold the SET button until the TEMP display ashes.
Set the desired temperature with (large ame) or (small
ame).
Press OFF or simply wait to complete programming.
Notice: When the desired room temperature is SET on the
hand held remote, the burner will automatically turn on when
the room temperature drops 3 degrees Fahrenheit (F) below
the SET temperature. The remote system will turn the burner
off when the room temperature reaches 3 degrees Fahren-
heit (F) above the SET temperature. The pilot will remain lit
between burner cycles when using the thermostatic remote
control feature.
SETTING THE TIMER
Select Timer mode by briey pressing the SET button.
Press and hold the SET button until the P1 (sun symbol)
is displayed and the time ashes. Set the hour by pressing the
(large ame) and set the minutes by pressing the (small
ame).
Briey press SET button for the next burner cycle time.
Example: P1 (moon symbol) continue through P2 (sun
symbol) and P2 (moon symbol).
Once all four (4) times are set, press OFF or simply wait to
complete programming.
MANUAL OPERATION
Follow appliance lighting instructions for gaining access to the gas
control and the pilot burner. Access to the pilot burner is only re-
quired for ignition with a match.
When turning main valve knob, do not force. Knob has a slip clutch
that clicks until the end stops are reached. This allows for manual
ame height adjustment as well as adjustment to pilot standby po-
sition.
1. STOP! Read the safety information included before proceed-
ing.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MANUAL knob to the MAN, full clockwise
position.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait ve (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the oor. If
you detect gas STOP! Follow "A" in the safety information on
page 26. If no gas is present, proceed to step 6.
6. Place ON/OFF switch in (ON position).
SETTING THE TIME
Display, Timer/Thermostat RF Remote Handsets
The display will ash after either:
a. Installing the battery or
b. Simultaneously pressing the (large ame) and (small
ame)
Press (large ame) to set the hour and the (small ame)
to set the minute.
Press OFF to return to manual mode or simply wait and it will
automatically return to the manual mode.
CHANGING THE MODE OF OPERATION
Briey pressing the SET button changes the mode of operation in
the following order:
Notice: MANUAL mode can also be reached by pressing either
the (large ame) or the (small ame).
and back to
MAN
Mode -
Manual Flame Height Adjustment
Press (large ame) to turn on the main burner.
Press (large ame) to increase the ame height.
Press (small ame) to decrease the ame height or to go to
pilot standby position.
Notice: While pressing either button a symbol indicating trans-
mission appears on the display. The receiver conrms
transmission with a beep.
TEMP
- Daytime Temperature Mode
(appliance must be in standby mode; pilot ignited): The room tem-
perature is measured and compared to the set temperature. The
ame height is then automatically adjusted to achieve the Daytime
set temperature.
TEMP
- Nighttime Setback Temperature Mode
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the Night-
time Setback temperature. The ame height is then automatically
adjusted to achieve the Nighttime Setback temperature.
TIMER
- Timer Mode
(appliance must be in standby mode; pilot ignited):
The timer setting allows you to set two (2) burner
TEMP
times
and two (2) burner
TEMP
times every 24 hours.
For
TEMP
to operate as a thermostat, TEMP must be set at
40°F (4°C) or higher.
If the
TEMP
setting is decreased to 39°F (3.9°C), the motor
will turn the valve to the standby position in the moon times and
await the next burner
TEMP
cycle.
MAN
TEMPTEMP
TIMER
MAN
INTERMITTENT PILOT REMOTE ELECTRONIC IGNITION AND CONTROL SYSTEM