Owner`s manual

27407-4-1010 Page 31
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Millivolt thermopile is self powered, gas valve does
not require 110 volts. Maximum length of 20 feet of
16 AWG to conductor wires is to be used with all
optional switches.
Use the two leads (Red and Green) to attach optional
components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be
checked with a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver
adjacent to the gas valve.
Attention: The remote receiver bracket is not used
in this installation.
1. The remote receiver can not be placed behind
the gas valve and burner assembly.
2. When facing the appliance, the remote receiver
must be placed to the right of the gas valve.
Install remote control receiver behind bottom
louver.
Refer to remote control installation and operating
instructions for more details on remote control.
Keep the control compartment and burner area clean by vacuuming
or brushing area at least twice a year.
THE FIREPLACE CAN GET VERY HOT HANDLE ONLY WHEN
COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the rating plate of the replace.
Never obstruct the ow of the combustion and ventilation air. Keep
the front of the replace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the replace.
Front should be installed during operation.
Figure 31
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150 ° CDUL'EQUIVALENT.
THERMOPILE
GAS VA LVE
THERMOCOUPLE
(NATURAL)
OFF
ON
REMOTE
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLEEDISTANCE
DU RECEPTEUR
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
WIRING DIAGRAM
GAS VA LVE
VA LVEDE GAZ
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
H N
VEILLEUSE
PILOT
THERMOCOUPLE
(LPG)
WIRING
MAINTENANCE