For proper burner operation and ame appearance, the ow of
primary air into the venturi tube, located on the rear of the burner,
must not be reduced. This ow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The ow of air into the
venturi is also reduced if the gas orice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of the
burner orice may be corrected by bending the shutter cap holding
the orice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
Ceiling fans or oscillating oor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly
into the ame causing it to disrupt the ame, disrupt the ame, it
should be turned off or redirected. Ceiling fans could be reversed
to possibly eliminate ame impingement, and the oor fan could
be redirected. Upon installation, be aware of any cold air returns
or vents in the proximity of the log set. Any draft created around
a vent-free log set can cause the ame to impinge on the log and
create a sooting situation.
WARNING
Do not allow fans to blow directly into the replace. Avoid any
drafts that alter burner ame patterns.
WARNING
Do not use a blower insert, heat exchanger insert or other
accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is
in operation. Candles produce a residue in the air that creates a
soot like substance. Burning candles while the log set is operating
magnies the problem. It should be noted that candles, in general,
produce soot. The amount of time burned and the quantity of
candles burned will determine the amount of soot produced and
deposited.