Heritage Vent Free Cast Iron Stove Installation Manual

31208-1-1112Page 20
SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS
IMPORTANT:

 
pilot.
a. Ignitor electrode positioned wrong - Replace ignitor.
 
 

 

 
f. Bad piezo ignitor - Replace piezo ignitor.
 
but no ignition.
a. Gas supply turned off or manual shutoff valve closed - Turn
on gas supply or open manual shutoff valve.
 
to PILOT position.
 

d. Air in gas lines when installed - Continue holding down control

e. Depleted gas supply - Contact local gas company.
f. ODS/pilot is clogged - Clean ODS/pilot or replace ODS/pilot

g. Gas regulator setting is not correct - Replace gas
regulator.
 
released.
  
fully.
 

       

to reset. Repeat ignition operation.
d. Manual Shutoff valve not fully open - Fully open manual
shutoff valve.
e. Thermocouple connection loose at control valve - Hand
tighten until snug, then tighten 1/4 turn more.
       

1) low gas pressure
- Contact local gas company or    
clogged ODS/pilot - Clean ODS/pilot or replace ODS/pilot

g. Thermocouple damaged - Replace thermocouple.
h. Control valve damaged - Replace control valve.
4. Main burner does not light after ODS/pilot is lit.
 

 

c. Inlet gas pressure is too low - Contact local gas company.
 
switch "ON."
a. "On/Off" switch, wall switch, remote control or wires defective

         
comes on, replace defective switch. If OK, place jumper


 

clean the ODS/pilot.
- Be sure the wire connections from the thermopile at the
gas valve terminals are tight and the thermopile is fully


at TH-TP & TP terminals of the gas valve. The meter should

depressed in the PILOT position, with the pilot lit, and the
ON/OFF switch in the OFF position. Replace the faulty

- With the pilot in the ON position, disconnect the thermopile



 
        
terminals. Millivolt meter should read greater than 200

not ignite, replace the gas valve
 

 
a. Manifold pressure is too low - Contact local gas company.
 

 
blow torch noise).
 
service person.
 
-

 
 
 
burner combustion.
 

 
MILLIVOLT TROUBLESHOOTING