Data Sheet

Holding Register
Desimal (Hex)
Addresses
Parameter
Number
Data
Type
Data Content
Read Write
Permission
/
Factory
Defauls
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
0000d (0000h)
400
0
600
4
2
40
100
20
0
0
0
400
500
0
600
600
XX
500
0
2
2
5
0
0
20
0
0
0
0
0
1
3
10
0
XX
0
0
XX
XX
50
000 d (000 h)1 1
000 d (000 h)2 2
000 d (000 h)3 3
000 d (000 h)4 4
000 d (000 h)5 5
000 d (000 h)6 6
000 d (000 h)7 7
000 d (000 h)8 8
000 d (000 h)9 9
00 d (000 h)10 A
00 d (000 h)11 B
00 d (000 h)12 C
00 d (000 h)13 D
00 d (000 h)14 E
00 d (000 h)15 F
00 d (00 0h)16 1
00 d (00 h)17 11
00 d (00 h)18 12
00 d (00 h)19 13
00 d (00 h)20 14
00 d (00 h)22 16
00 d (00 h)21 15
00 d (00 h)23 17
00 d (00 h)24 18
00 d (00 h)25 19
00 d (00 h)26 1A
00 d (00 h)27 1B
00 d (00 h)28 1C
00 d (00 h)29 1D
00 d (00 h)30 1E
00 d (00 h)31 1F
00 d (00 h)32 20
00 d (00 h)33 21
00 d (00 h)34 22
00 d (00 h)35 23
00 d (00 h)36 24
00 d (00 h)37 25
00 d (00 h)38 26
00 d (00 h)39 27
1.1 Memory Map for Holding Registers
H1
H0
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H23
H22
H24
H25
H26
H27
H28
H29
H30
H31
H32
H33
H34
H35
H36
H37
H38
H39
Control output, temperature setpoint value
Alarm1 output temperature setpoint value
Control output, time period setpoint value (Adjustable between 1 and 125 second)
Control output, soft start value
Control output, 2nd temperature setpoint value
Alarm1 output type selection Values can be given from 0 to 4 Independent alarm
Deviation alarm Active alarm after in band time
Alarm1 output, cooling control selection
( ) (0 = ,
1 = , 2 = Band alarm, 3 = ,
4 = )
Alarm2 output type selection Values can be given from 0 to 3 Independent alarm
Deviation alarm Active alarm after in band time
( ) (0 = ,
1 = , 2 = Band alarm, 3 = )
ModBus device address (Adjustable between 1 and 247)
Modbus communication speed (Baudrate) (0 = Modbus cancel, 1 = 2400 bps, 2 = 4800 bps,
3 = 9600 bps, 4 =19200 bps, 5 = 38400 bps)
Digital filter coefficient Adjustable between and , = filter is disable ( 1 200 1 )
Control output, selection value C/A2 Control output selection SSR Output ( = , = )0 1
Reserved
Reserved
Manual control output percentage Adjustable between and ( %0 %100)
Offset value
Function control parameter.
( 23040d ( 5A00h ) )
( 23041d ( 5A01h ) )
( 23042d ( 5A02h ) )
self tune stops when this value is entered
self tune starts when this value is entered
returns to factory defaults when this value is entered
Control output, minimum setpoint value
Alarm1 output minimum setpoint value limit
Control output, maximum setpoint value
Alarm1 output maximum setpoint value limit
Control output, proportional band setpoint value (Adjustable between %0 and %100 ).0 .0
Alarm1 output proportional band set value (Adjustable between %0 and %100 ).0 .0
Control output, set value power ratio (Adjustable between %0 and %100)
Control output, set value power ratio in case of sensor failure (Adjustable between %0 %100)and
Control output, hysteresis value or 1 °C °F(Adjustable between and 50 )
Alarm1 output hysteresis value or 1 °C °F(Adjustable between and 50 )
Control output, integral time minute 0.1 100.0(Adjustable between and )
Control output, derivative time minute 0.01 10.00(Adjustable between and )
ENDA ET SERIES PID TEMPERATURE CONTROLLER
MODBUS ADDRESS MAP
Input selection number (0 = PT100 Decimal, 1 = Pt100 Non-decimal, 2 = J Decimal,
3 = J Non-decimal, 4 = K Decimal, 5 = K Non-decimal, 6 = L Decimal, 7 = L Non-decimal,
8 = T Decimal, 9 = T Non-decimal, 10= S Non-decimal, 11 = R Non-decimal.
Alarm1 output, integral time minute 0.1 100.0(Adjustable between and )
Alarm1 output, derivative time minute 0.01 10.00(Adjustable between and )
Alarm1 output, time period setpoint value (Adjustable between 1 and 125 second)
Alarm1 output, set value power ratio (Adjustable between %0 and %100)
Alarm1 output, set value power ratio in case of sensor failure (Adjustable between %0 %100)and
Alarm2 output, temperature setpoint value
Alarm2 output minimum setpoint value limit
Alarm2 output maximum setpoint value limit
Alarm2 output, hysteresis value or 1 °C °F(Adjustable between and 50 )
Reserved
Reserved
ETx420-E-Modbus-10052019
1. / 3
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
/ D-72160 Horb a.NDettinger Str. 9