User Manual

E08
CH1 Output Short Circuit
This means there is a Short Circuit on the DC output to your Main/House battery.
If this is displayed, check the following:
The output wires are not shorted together.
The output wires are wired correctly and not reverse polarity.
A01
Over Temperature Warning
When the charger’s internal temperature is > 60°C, the unit will shut down to protect itself. The unit will return back to
normal charging once the internal temperature is < 58°C
Check to make sure the fan is working.
Make sure the unit has good ventilation.
A02
BTS High Temperature Warning
When the battery temperature sensor is > 58°C, the unit will shut down to protect the batteries. The unit will return
back to normal charging once the battery temperature sensor is < 56°C.
Check to make sure the batteries are not hot.
Make sure the batteries have good ventilation.
8. SPECIFICATIONS
Output Rating
Output Voltage 24V Nominal (17.0V min)
Output Current 30A
Output Power 865W
Charger DC Output (CH1):
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program
Charger Voltage Range 27.6V – 31.0V
Float Voltage Range 26.0V – 27.6V
Charger Current (User Selectable) 5 / 10 / 20 / 30A (default 30A)
Equalize Voltage (Flooded Battery) 31.0V
Equalize Charging Current 10% of Bulk Current Setting
Charging Control
2 stage / 3 stage selectable
(Default 3 stage)
DC Output Bank Single
Current draw from CH1 when not operating = < 50mA
Battery Temperature Setting
Low/ Normal/ High
(Battery Temperature Sensor Standard)
Eciency 95%
INPUT Rating (CH2 - MPPT Solar)
Input Voltage 14.5 - 45VOC
Maximum Solar Input
≤ 23V input, 500W (600W allowable)
≥37.5V-45V input, 800W (1000W allowable)
INPUT Rating (CH3 - Start/Alternator)
Input Voltage 10.5 - 16VDC / 21 - 32VDC
Dimensions
Height x Width x Depth 242mm x 172mm x 74mm
Unit Weight 1.85 Kg
Shipping Weight 2.17 kg
Note: Specications are subject to change without notice.
Enerdrive ePOWER DC2DC 24V Battery Charger Owners Manual (Rev. 1.5) www.enerdrive.com.auPage 32 Page 33