User Manual
E08
CH1 Output Short Circuit
This means there is a Short Circuit on the DC output to your Main/House battery.
If this is displayed, check the following:
• The output wires are not shorted together.
• The output wires are wired correctly and not reverse polarity.
A01
Over Temperature Warning
When the charger’s internal temperature is > 60°C, the unit will shut down to protect itself. The unit will return back to
normal charging once the internal temperature is < 58°C
• Check to make sure the fan is working.
• Make sure the unit has good ventilation.
A02
BTS High Temperature Warning
When the battery temperature sensor is > 58°C, the unit will shut down to protect the batteries. The unit will return
back to normal charging once the battery temperature sensor is < 56°C.
• Check to make sure the batteries are not hot.
• Make sure the batteries have good ventilation.
8. SPECIFICATIONS
Output Rating
Output Voltage 24V Nominal (17.0V min)
Output Current 30A
Output Power 865W
Charger DC Output (CH1):
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program
Charger Voltage Range 27.6V – 31.0V
Float Voltage Range 26.0V – 27.6V
Charger Current (User Selectable) 5 / 10 / 20 / 30A (default 30A)
Equalize Voltage (Flooded Battery) 31.0V
Equalize Charging Current 10% of Bulk Current Setting
Charging Control
2 stage / 3 stage selectable
(Default 3 stage)
DC Output Bank Single
Current draw from CH1 when not operating = < 50mA
Battery Temperature Setting
Low/ Normal/ High
(Battery Temperature Sensor Standard)
Eciency 95%
INPUT Rating (CH2 - MPPT Solar)
Input Voltage 14.5 - 45VOC
Maximum Solar Input
≤ 23V input, 500W (600W allowable)
≥37.5V-45V input, 800W (1000W allowable)
INPUT Rating (CH3 - Start/Alternator)
Input Voltage 10.5 - 16VDC / 21 - 32VDC
Dimensions
Height x Width x Depth 242mm x 172mm x 74mm
Unit Weight 1.85 Kg
Shipping Weight 2.17 kg
Note: Specications are subject to change without notice.
Enerdrive ePOWER DC2DC 24V Battery Charger Owners Manual (Rev. 1.5) www.enerdrive.com.auPage 32 Page 33