User Manual

DC2DC 24V Battery Charger Connections
SOLAR INPUT SOLAR INPUTBATTERY INPUT BATTERY INPUT BATTERY OUTPUT BATTERY OUTPUTIGNITION SENSE
TERMINAL
Battery
Temperature
Sensor Port
Unit Ground
Recommended Cable Length, Size and Fuse Protection.
DC2DC Connection
Inputs
Require Length & Battery Cable Size
DC2DC set to
=<30A Output
2 Meters to 5
Meters (2)
Up to 10
Meters (2)
Greater than
10 Meters
From Alternator Battery
6-16mm
2
@ 12vdc
/ 4-8mm
2
@ 24vdc
16-35mm
2
@ 12vdc
/ 8-16mm
2
@ 24vdc
Not Recommended
Primary Battery
Connection (2)
16mm
2
Not Recommended Not Recommended
Note: Cable size quoted is one way from battery to device, however suggested cable size is calculated with return run.
1) Note: If solar panels are wired in Series (increased voltage), then typically 1 x 4mm
2
cable run per series string
is suitable.
2) Based on 3% voltage drop.
Recommended Fuse Protection
From Alternator Battery
12V Alternator = 70amp Fuse or Circuit Breaker
24V Alternator = 40amp Fuse or Circuit Breaker
*No greater than 20cm from source battery.
PLEASE NOTE: Automatic re-settable circuit breakers are
NOT recommended.
From Solar Panels
Fusing recommended no greater than 20cm from input to DC2DC
24V Charger. Typically 15amps per solar panel (consult your panel
specications for further details).
Primary Battery
Connection
40amp Fuse or Circuit Breaker.
Standard Temperature Sensor Connection
To install the temperature sensor, simply connect the RJ12 plug from the sensor to the
RJ12 Temperature Sensor Port located next to the Remote Port.
On the temperature sensor end, simply connect the ring terminals to the negative terminal
of the main house battery bank.
PLEASE NOTE: For lithium installations, the standard supplied temperature sensor is not
required to be installed for these applications.
Start Battery House BatterySolar Array
CH2 CH1CH3
Enerdrive ePOWER DC2DC 24V Battery Charger Owners Manual (Rev. 1.5) www.enerdrive.com.auPage 16 Page 17