Manual

5. FAULT INDICATOR
When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same time.
Blinking
Frequency
(Every 4 sec)
Fault Cause Solution
1
The battery is not connected or the
battery voltage is too low
1) Check battery connection is correct.
2) Check charger connection is correct.
Check each battery is good.
2 Abnormal AC Power Input (Voltage)
1) Check AC input cord is connected between charger and AC
outlet.
2) Make sure AC plug is tightly inserted into AC outlet.
3 Charger High Temperature Protection
1) Charger shuts down and enters protection mode due to
charger/environmental temperature is too high. Please place
the charger in a well-ventilated environment.
2) Disconnect the charger and wait for 15-20mins before
reconnecting.
4 Battery High Temperature Protection
1) Charger will reduce output current and stop charging when
the battery temperature exceeds 50°.
2) Disconnect the charger and wait for 15-20 mins before
reconnecting for charging.
5 Output Current is too large Return to the factory for repair.
6 Battery voltage is too high
Check and assure that the correct output battery voltage is
connected.
7 Battery voltage is too low Check that the correct output battery voltage is connected.
Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.2)Page 10