Recommended Fuse Protection
From Alternator Battery
70amp Fuse or Circuit Breaker no greater than 20cm from source
battery.
PLEASE NOTE: Automatic re-settable circuit breakers are
NOT recommended.
From Solar Panels
Fusing recommended no greater than 20cm from input to DC2DC+
Charger. Typically 15amps per solar panel (consult your panel
specications for further details).
Primary Battery
Connection
60amp Fuse or Circuit Breaker.
Standard Temperature Sensor Connection
•
To install the temperature sensor, simply connect the RJ12 plug from the sensor to the
RJ12 Temperature Sensor Port located next to the Remote Port.
•
On the temperature sensor end, simply connect the ring terminals to the negative terminal
of the main house battery bank.
PLEASE NOTE: For lithium installations, the standard supplied temperature sensor is not
required to be installed for these applications.