User Manual
Understanding the Display & Function Keys during normal operation
Display
Digital Display LCD with back lighting
Digital Display Info : CH1
CH2 & CH3
Fault/Warning
Charging Status, Voltage, Current
Voltage
Error code E01-08, Warning A01-02
‘CH3’ Icon Flashing
CH3 > 12.0V on a 12V Input system
CH3 > 24.0V on a 24V Input system
and not charging from (alternator)
‘CH3’ Icon Solid Charging from CH3 input (Start Battery / Alternator)
‘CH2’ Icon Flashing CH2 > 14.5V and not charging from solar array
‘CH2’ Icon Solid Charging from CH2 input (solar)
•
During normal operation, the display will cycle through and show CH1 battery voltage,
charging current and charging stage (‘bul’ – Bulk stage, ‘Abs’ – Absorption stage, ‘Ful – Float
stage) alternatively. When the ‘MENU’ key is pressed, it will display the other channel’s
battery voltage only
•
CH3 icon will ash when the input voltage is above (> 12 on a 12V system or > 24V on a
24V system and it is not the source charging the battery. It will change to solid when it
becomes the source charging the battery.
• CH2 icon will ash when the input voltage is above the Flashing Voltage (> 14.5V) and is
not the source charging the battery. It will change to solid when it becomes the source
charging the battery.
•
During normal operation, Every time the menu button is pressed once, the display will
scroll through and show CH1, CH2 & CH3: Voltage’ for 3 seconds and it will return to the
normal display automatically. If CH2 or CH3 is not connected, it will show 0V.
• The display will remain ON when either one or both CH2 & CH3 inputs are available. The
display will turn OFF if CH2 or CH3 is not available.
•
During equalisation operation (for ooded batteries only), the numerical section on the
display will show a ashing ‘eq’ indicating the equalisation process is in progress and it
will not show the battery voltage or the charging current.
www.enerdrive.com.au Page 25