User Manual

Press SEL
to enter Max
Current Menu
Press SEL
to enter
Termination
Current Menu
Press SEL
to change
current
NOTE: At any function setting, pressing the MENU button will exit the function mode.
WARNING: FIRE HAZARD
When using the Lithium Battery type setting to set the battery charging parameters, please consult the battery manufacturer on all the
voltage and current settings. Using the wrong setting to charge battery may overcharge, damage the battery and may cause a re.
CH1 LITHIUM
CHARGING CURRENT
CH1 LITHIUM BATTERY
TERMINATION CURRENT
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep
the current setting
and toggle to the
next menu
Press SEL
to return
to change
current
Press SEL
to return to
change current
Press MENU to exit settings
Press SEL
to change
current
Press SET to keep the
current setting and
toggle to the next menu
CH1 Absorption to Float Current “L” Setting
This setting is used to determine when the battery
is full. Once the current ow reaches this number or
below, the charger deems the battery to be full and
will shift the charger to the oat state. If running
constants loads i.e. Fridge etc, set the charger to the
highest “L” number: Choose between 1 to 10A
(Subject to H setting see page 11)
CH1 Bulk Current “h” setting
This setting is used to determine the maximum
output current that the charger is capable of. For
currents 40A or higher, this is achievable if the input/
output cables are large enough for the given distance
to carry the maximum voltage.
Choose between 5 to 50A (5A increments)
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep the
current setting and
toggle to the next menu
Press SET to keep the
current setting and
toggle to the next menu