User Manual

Model EN31220 EN31240 EN31260 EN32430
Cooling Forced air ventilation
Temperature Setting Hot, Normal, Cold (no sensor connected)
Battery Temperature
Sensor Port
RJ12 (standard battery temperature sensor supplied)
Digital Display Port RJ12 (optional display panel available)
Display:
LCD Display Backlit display. Charging status, Battery Voltage and Output Current
Warning and Fault Code Shown on display
AC Input and DC Output Connection:
AC Input Connection IEC with Supplied 1.2M Power Lead
DC Output Connection Heavy Duty Terminal (3 banks). 6mm ring terminals.
DC Output Ground Single Heavy Duty Common Ground Stud. 6mm ring terminals.
Environmental and Operating Temperature:
Storage Range -40° to 70° C
Operating Range -20° to 60° C
Humidity 5-95%, RH non-condensing
Ingress Protection
IP32 - Protected against solid objects over 2.5mm
and water sprays up to 15º from vertical.
Base Unit Weight and Dimensions:
EN31220 2.4 Kg / 295 x 206 x 86 mm
EN31240 2.6 Kg / 295 x 206 x 86 mm
EN31260 / EN32430 4.0 Kg / 356 x 206 x 99mm
Optional Accessories: Remote Digital Display / Enerdrive Part Number EN3REM
Regulatory Compliance: Complies with AS/NZS 60335.2.29 Including Australian deviations.
Note: Specications are subject to change without notices.
Page 33www.enerdrive.com.au