User's Manual

Battery Wiring (Towing Applications):
For Towed Applications i.e. Caravans, Camper Trailers
(Optional Ignition - On)
VSO
(Voltage Sense Override)
Anderson Plug (Optional)
MPPT Solar Panel Input
Max: 500w / 45VOC
(For xed or portable panels)
Start / Vehicle Battery
12V or 24V
Fuse / Breaker
12V - 70A
24V - 40A
Fuse Size 1A
Fuse / Breaker
Fuse / Breaker
60A
Temp Sensor Cable
(Included)
12V House Battery Bank
This diagram is for a reference only. No cables, fuse/breakers, batteries or solar panels are supplied with this unit.
Local rules and regulations should be followed when installing this unit.
Please NOTE
The negative cable from the start battery must
be carried to the DC2DC input terminal for
correct operation in a towed application.
Smart alternator
battery sense
module.
Please NOTE
Vehicles with a Smart alternator,
the Negative cable must be
connected to the vehicle side of
the Battery Sense Module.
POSITIVE WIRE
NEGATIVE WIRE
TEMPERATURE SENSOR
CABLE (INCLUDED)
www.enerdrive.com.au Page 19