Specifications

Solution 3.4 Installation and Operation Manual
27
7 Clearances to Combustible Material
The clearances shown in this section have been determined by test according to procedures set
out in safety standards ULC S627 (Canada) and UL1482 (U.S.A.). When the stove is installed so
that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not
overheat under normal and even abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the minimum
clearances given below.
7.1 Location of the certification label
Since the information given on the certification label affixed to the appliance always overrides the
information published, in any other media (owner’s manual, catalogues, flyers, magazines and/or
web sites) it is important to refer to it in order to have a safe and compliant installation. In addition,
you will find information about your stove (model, serial number, etc.). You can find the certification
label on the back of the stove.
7.2 Clearances to Walls and Ceiling
The clearances to combustible walls may be slightly different in Canada and the U.S.A. and may
also differ depending on whether you use single or double wall flue pipe. Please be sure to choose
the correct clearance for your location and type of flue pipe. See figure Clearances to
combustible materials and floor protection to match each letter to a clearance.
CLEARANCES
(SINGLE WALL PIPE)
CANADA USA
A
19” (485 mm) 19” (485 mm)
B 19” (485 mm) 19” (485 mm)
C
11” (280 mm) 11” (280 mm)
D
23” (585 mm) 23” (585 mm)
E
30” (765 mm) 30” (765 mm)
F
23” (585 mm) 23” (585 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)
CLEARANCES
(DOUBLE WALL PIPE)
CANADA USA
A
10” (255 mm) 10” (255 mm)
B 14” (360 mm) 14” (360 mm)
C
8” (205 mm) 8” (205 mm)
D
14” (360 mm) 14” (360 mm)
E
25” (635 mm) 25” (635 mm)
F
20” (510 mm) 20” (510 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)