Product Manual

- 21 -
In ambient temperature below 0(32), the engine will run at the rated
r/min (4500r/min) for 5 minutes to warm up the engine.
In ambient temperature below 5(41), the engine will run at the rated
r/min (4500r/min) for 3 minutes to warm up the engine.
The ESC unit operates normally after the above time period, while the ESC
is “ON”.
TIPTurn off any electric devices.
6.2 Stopping the engine
1.Turn the ESC to “OFF” ①.
2.Disconnect any electric devices.
3 Turn the 3 in 1 switch to “OFF” ②,
a. Ignition circuit is switched off.
b. Fuel is switched off.
.
4 Turn the fuel tank cap air vent knob to
“OFF” after the engine has completely
cooled down.
.
- 22 -
Be sure any electric devices are turned off before plugging them in.
6.3 Alternating Current (AC) connection
Be sure all electric devices including the lines and plug connections are
in good condition before connection to the generator.
Be sure the total load is within generator rated output.
Be sure the receptacle load current is within receptacle rated current.
TIP: Make sure to ground (Earth) the generator. When the electric device is
earthed, always the generator must be earthed.
1. Start the engine.
2. Turn the ESC to “ON”.
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electric devices.
TIP: The ESC must be turned to “OFF” to increase engine speed to rated rpm.
If the generator is connected to multiple loads or electricity consumers, please
remember to first connect the one with the highest starting current. and last
connect the one with the lowest starting current.
-21-