Specifications Sheet

To learn more about Enphase offerings, visit enphase.com
© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc.
2018-01-25
INPUT DATA (DC) IQ6-60-2-US IQ6PLUS-72-2-US
Commonly used module pairings¹ 195 W - 330 W + 235 W - 400 W +
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
MaximuminputDCvoltage 48 V 62 V
Peak power tracking voltage 27 V - 37 V 27 V - 45 V
Operating range 16 V - 48 V 16 V - 62 V
Min/Maxstartvoltage 22 V / 48 V 22 V / 62 V
MaxDCshortcircuitcurrent(moduleIsc) 15 A 15 A
OvervoltageclassDCport II II
DCportbackfeedundersinglefault 0 A 0 A
PVarrayconguration 1x1ungroundedarray;NoadditionalDCsideprotectionrequired;
ACsideprotectionrequiresmax20Aperbranchcircuit
OUTPUT DATA (AC) IQ 6 Microinverter IQ 6+ Microinverter
Peak output power 240 VA 290 VA
Maximumcontinuousoutputpower 230 VA 280 VA
Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V
Maximumcontinuousoutputcurrent 0.96 A 1.11 A 1.17 A 1.35 A
Nominal frequency 60 Hz 60 Hz
Extendedfrequencyrange 47 - 68 Hz 47 - 68 Hz
Power factor at rated power 1.0 1.0
Maximumunitsper20A(L-L)branchcircuit 16 (240 VAC) 13 (240 VAC)
14 (208 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed under single fault 0 A 0 A
Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
CECweightedefciency 97.0 % 97.0 % 97.0 % 97.0 %
MECHANICAL DATA
Ambient temperature range -4C to +65ºC
Relative humidity range 4% to 100% (condensing)
Connector type MC4 locking type
Dimensions(WxHxD) 219mmx191mmx37.9mm(withoutbracket)
Weight 1.29 kg (2.84 lbs)
Cooling Natural convection - No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated
Environmentalcategory/UVexposurerating NEMA Type 6 / outdoor
FEATURES
Communication Power line
Monitoring Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy
Disconnectingmeans TheACandDCconnectorshavebeenevaluatedandapprovedbyULforuseastheload-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO. 107.1-01
ThisproductisULListedasPVRapidShutDownEquipmentandconformswithNEC-2014and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC
andDCconductors,wheninstalledaccordingmanufacturer’sinstructions.
1.NoenforcedDC/ACratio.Seethecompatibilitycalculatorat https://enphase.com/en-us/support/module-compatibility.
2.Nominalvoltagerangecanbeextendedbeyondnominalifrequiredbytheutility.
Enphase IQ 6 and IQ 6+ Microinverters