IQ7 Micro Installation

IQ 7 / IQ 7+ / IQ 7X Micro Installation and Operation
© 2018 Enphase Energy Inc. All rights reserved. 141-00043-02
23
Method 1: Clear this Error Using Enlighten
Log in to Enlighten and access the system.
Click the Events tab. The next screen shows a current “DC Resistance Low - Power Off
condition for the system.
Click DC Resistance Low - Power Off.
Where “n” is the number of affected devices, click n devices (show details).
Click the serial number of the affected microinverter.
Click Reset DC Resistance Low - Power Off Sensor.
The system displays, “A DC Resistance Low- Power Off reset task was issued on [date and time]
for this microinverter and is still pending.”
Method 2: Use Installer Toolkit to Clear the Condition
On the list of detected microinverters, a green dot or red square appears to the left of each microinverter
serial number. A green dot indicates Status OK. A red square indicates an event for that microinverter.
Tap the to the left of the serial number to view details for a microinverter event.
If the microinverter status shows that there is an active DC Resistance Low Power Off
condition, tap the to send the clear message to the affected microinverter.
The app then indicates that a clear message was sent.
Other Faults
All other faults are reported to the Envoy. Refer to the Enphase IQ Envoy Installation and Operation
Manual at
enphase.com/support for troubleshooting procedures.