Device Events and Alarms
Event and Alarm Messages Fast Ethernet SmartSwitch Module
4-2 Management Module Guide
CsEvFormat/Event00010308
{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected a
communication Link Down. (event
[{e}])
CsPCause/Prob00010308
Communication link is down.
CsEvFormat/Event00010309
{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected a
communication Link Up. (event [{e}])
No probable cause message
CsEvFormat/Event0001030a
{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected an
Authentication Failure. (event [{e}])
CsPCause/Prob0001030a
Authorization failure. Other user is trying to
connect to device with an invalid community
string.
CsEvFormat/Event0001030b
{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected an
EGP Neighbor Loss. EGP Neighbor
IP address is {0 1}. (event [{e}])
CsPCause/Prob0001030b
Lost contact with EGP neighbor.
CsEvFormat/Event000d01a0
{d “%w- %d %m-, %Y - %T”} - A Port
Interface Module has been inserted
into port {I 3} of interface {I 1} on {m}
({t}). (event [{e}]).
CsPCause/Prob000d01a0
A Port Interface Module has been physically
inserted.
CsEvFormat/Event000d01a1
{d “%w- %d %m-, %Y - %T”} - A Port
Interface Module has been removed
from port {I 3} of interface {I 1} on
{m} ({t}). (event [{e}])
CsPCause/Prob000d01a1
A Port Interface Module has been physically
removed.
CsEvFormat/Event000d01a2
{d “%w- %d %m-, %Y - %T”} -
Network configuration change
reported by {m} ({t}). Device linked to
port {I 3} on interface {I 1}. (event
[{e}])
CsPCause/Prob000d01a2
A device supporting link integrity, fiber optic or
twisted pair, has made a valid connection (link)
to this port.
Table 4-1. Fast Ethernet SmartSwitch Module Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message