User's Manual

Pre-Installation Tasks
1-8 DC Power Supply Installation
Prepare Site Wiring for DC Power Installation
1. Ensurethatabranchcircuitdisconnectdeviceisinstalled,andthatthedeviceis
switchedtopreventpowerfrombeingsuppliedtotheDCpowersupply.
2. Ifdesired,attachyourwiringtothe2holecompressionlugsprovided.
Foryourconvenience,EnterasysNetworksshipswiththeDCpowersupplytwo
2hole
compressionlugstowhichyoucanconnectyourwiring(6AWG).These
compressionlugsarethecorrectsizetofitoverthepositiveandnegativeterminal
studs.SeeChapter 2,DCPowerSupplySpecificationsformoredetailsaboutthe
compressionlugs.
Table 1-3 Minimum Revision of X Modules for DC Power
Model Name Minimum 940 Part Number Minimum 940 Revision
X-CM-00 4179 5A
1
1. Exception: If an X-CM-00 module meets the Minimum 940 Part Number revision and has a 2
digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power-
compliant.
X-T32-00 4167 5A
2
2. Exception: If an X-T32-00 module meets the Minimum 940 Part Number revision and has a 2
digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power-
compliant.
X-G32-00 4161 5A
3
3. Exception: If an X-G32-00 module meets the Minimum 940 Part Number revision and has a 2
digit 940 revision code of 4X (for example, 41, 42, and so on), the module is DC power-
compliant.
X-M2-00 4054 5H
X-M8-01 4162 5A
X-GT16-00 3977 5A
X16-FM 4059 5C
X8-FM 4055 5B
X4-FM 4050 5B
X-FAN 4085 5B
X-FAN-AC N/A N/A