User's Manual

Power Supply Redundancy
Matrix X Router DC Power Supply Installation Guide 2-3
Table 2-3 Module Power Specifications
Module
@ 48 VDC
Power (Watts) Thermal Output (BTU/HR)
CM 97 Watts 331.1 BTU/HR
Fan tray 85 Watts 290.1 BTU/HR
X4-FM 30 Watts 102.4 BTU/HR
X8-FM 62 Watts 211.6 BTU/HR
X16-FM 98 Watts 334.5 BTU/HR
X-GT16-00 155 Watts
1
1. The actual power draw of the X-GT16-00 is 105 Watts. However, for the purposes of budgeting the
number of power supplies required, use 155 Watts.
520.0 BTU/HR
X-T32-00 155 Watts 520.0 BTU/HR
X-G32-00 155 Watts 520.0 BTU/HR
X-M2-00 155 Watts 520.0 BTU/HR
X-M8-01 190 Watts 648.0 BTU/HR
Table 2-4 Redundancy Configurations for DC Power Supply
No. of Power Supplies Max Redundant System Load
1
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Redundancy Configuration
2 1500 Watts 1 + 1
3 3000 Watts N + 1
4 3000 Watts 1 + 1
4 4500 Watts N + 1
5 6000 Watts N + 1
6 4500 Watts 1 + 1
6 6000 Watts N + 1