- Enterasys Security Router User's Guide

System Alarms and Events
XSR User’s Guide A-11
Refer to the table below for all Low severity alarms and events reported by the XSR. All of the
following messages are USER_LEVEL facility except for those in bold text which are
SECURITY_LEVEL.
ETH0_
DRIV
PHY write operation unsuccessful The PHY chip on the FastEthernet 1 interface has had an error (other
than time-out) while processing a write request. When this occurs, port
functionality may or may not be affected. The port will still be available,
but its functionality may be diminished. The cause of this alarm is most
likely HW failure.
DIAL Dial muxIoctl call fail Failure of the serial driver of the physical port connected to the
modem.
DIAL Modem on intf # is not responding The modem is not connected or powered on.
DIAL Invalid init string for modem on intf # The modem does not recognize the initialization string. You should
check the modem specification for a proper setup.
DIAL Number busy for modem on intf # The remote site dialed number is busy.
DIAL No dial tone for modem on intf # There is no dial tone for the modem PSTN line.
DIAL No carrier for modem on intf # The remote modem is not present at the site called by the local
modem.
DIAL No answer for modem on intf # The remote modem is not configured for autoanswering.
DIAL Connection dropped for modem on intf#s The phone line connection is disconnected by the PSTN.
DIAL Hangup fail for modem on intf # Failure of the disconnect from the phone line command to the modem.
DIAL Connection closed for modem on intf # The phone line disconnect command is successful.
DIAL Dialup connection opened for modem on
intf #
The modem has successfully built a phone line link with the remote
site.
CLI Failed to create session for Telnet access Telnet session could not be created at this time.
CLI Unrecognized parameter <parameter
string> at line <line #> in <file>
Invalid parameters from initialization configuration file during boot
process. This file is different from the startup.cfg.
FR serial a/b:d, started
Result from
no shutdown command
FR serial a/b:d, shutting down
Shutdown command
FR serial a/b:d, station up, DLCI nnn
FR serial a/b:d, unknown LMI message Cannot decode the received LMI Message.
FR Serial a/b:d, dlci nn, No InVArp response
from remote
The remote peer is not responding to Inverse ARP requests.
FR Max. packet size based on CIR,BC,BE is
less than 1514 bytes
Table A-7 Medium Severity Alarms/Events (continued)
Module Message Description
Table A-8 Low Severity Alarms/Events
Module Message Description
T1E1 Receiver has Loss of Signal (Red Alarm). Indicates that T1/E1 physical port is detecting LOS Alarm.
T1E1 LOS alarm on receiver cleared. Indicates that T1/E1 physical port is not detecting LOS Alarm.