12. REPLACEMENT PARTS LIST( See appendix)
13.Auto White Balance Procedure
1 Connect signal to monitor. The display signal need contain real black and full white.
2 Press "Auto" button(don't release) when power ON(LED display Amber).
3 Press OSD select FACTORY 2, Auto Color, RUN(For AD converter calibration on R, G and B gain, offset).
4 Select Color Update, RUN.
5
Press OSD select COLOR into 6500 and check by color analysis (If adjustment Press OSD select FACTORY 1 for
Adjust the R, G, B gain. Please make color update when finished adjustment on 6500)
6
Press OSD select COLOR into 9300 and check by color analysis (If adjustment Press OSD select FACTORY 1 for
Adjust the R, G, B gain. Please make color update when finished adjustment on 9300)
Please make sure that Brightness set 100, Contrast set 80 when adjust(factory default).
*
The adjustment result needs to be checked by Color Analysis like CA110, the input signal 0.7V
and full white pattern while on check.