2. Getting started DLR24/xx-466 with 19-pole spring clamp terminal
1. Select modes:
put jumper 1 on 1-2 for internal speed reference (potentiometer 1) or
on 2-3 for external speed reference
(for internal reference put jumper 2 on 1-2 for value max. 5V DC)
put jumper 2 on 1-2 for speed reference max. 5V or on 2-3 for max.
10V DC target value input.
put jumper 3 on 1-2 for 12V motor or on 2-3 for 24V motor.
put DIP switch 1 and 2 ON for inverted enables (no need of connecting
terminal 15, 16 und 18)
put DIP switch 3 to 8 Off
2. Turn potentiometer 2 (Imax) for current limitation to the right position.
3. Potentiometer 3 (IxR) compensation to left position.
4. Connection of the control wires see Connection diagram, page 7.
5. Connect DC motor to terminals 3 and 4.
6. Connect power supply: to terminal 1 Plus (ca. 10 36V DC), to terminal 2
GND.
7. Now turn on power supply.
8. LED green (power on) illuminates on the pcb.
9. With potentiometer 1 (n ref) the speed reference can be adjust from 0 to
100%, if jumper 1 is put on 1-2.
10. Motor direction can be changed witch a voltage (5 36V DC) on terminal
19 (e.g. bridge from clamp 17 to 19)