User manual

Seite 5 von 10
Stand: August 2018 Z319-MG
3. Technical features
Power supply Ue: 10V DC – 36V DC (with inverse-polarity protection)
High frequency f>20 kHz, this results in low-noise operation
Electric connection via spring clamp terminals
High level of effectiveness by using Power Mosfets
Mounting: mounted with screws or on a 35mm mounting rail
The dispose of this product has to be done via separate electrical- and electronic
equipment disposal.
4. Technical data
Supply
Voltage
Armature voltage
U
A
Armature
current I
N
Mechanical power
P
ab
DLR 24/ 05 10-36V DC 0 - 12/24V DC 0 - 5A approx. 75W
DLR 24/ 10 10-36V DC 0 - 12/24V DC 0 - 10A approx. 150W
Model: DLR 24/xx/P: screw mounting
DLR 24/xx/M: screw mounting or mounting rail 35mm
DLR 24/xx/G: screw mounting or mounting rail 35mm
with yellow cover
Protection: external fuse: DLR 24/05 5AT
DLR 24/10 10AT
Environment temperature: 5° to 45°C
Relative air humidity: 18% to 85% (non-condensating)
Control range: up to 1 : 30
Speed control through EMF control with I x R compensation.