Specifications

EPSON EPL-N1600 Chapter 4 Disassembly and Assembly
Rev. A 4-141
4.3.32 Sensor Assembly Temperature
1. Remove the Cover Side,E. (Section 4.2.1)
2. Remove the Control Assembly Panel (E). (Section 4.2.3)
3. Remove the Cover Assembly MBF.E.(Section 4.2.4)
4. Remove the Tray Assembly MBF.E.(Section 4.2.5)
5. Remove the Cover Assembly,E. (Section 4.3)
6. Remove the Roll Assembly Exit Out. (Section 4.3.27)
7. Remove the Fuser Assembly. (Section 4.3.31)
8. Remove Roll Assembly Exit.(Section 4.3.34)
9. Remove the Roll Fuser and Heater Quartz from the Fuser
Assembly.(Section 4.3.36)
10. Remove the screw that secures the Sensor Assembly Temperature
to the Fuser Frame.
11. Disconnect J292.
Figure 4-38. “Sensor Assembly Temperature” Removal
CAUTION
Do not touch the surface of the Roll Fuser. Hold the
ends of the Roll Fuser when handling the Roll Fuser.
Do not touch the Heater Quartz with your fingers.
Hold the Heater by the metal tabs that are attached to
the ends of the Heater when handling the Heater
Quartz.