Administrator's Guide

Settings/Maintenance
29
Auto Cleaning
From the CR Unit Adjustment/Maintenance (03) menu, click Auto Cleaning (0311) from Head Cleaning (031) to
display the screen.
A
Click Auto Cleaning.
Nozzle check begins, and cleaning is performed as necessary.
This may take some time depending on the status of the nozzles.
B
Check the status of each head displayed in the Result.
When the nozzles are cleared, "Good" is displayed.
If nozzles are clogged, a message is displayed that indicates you need to clean the Print Head Unit again.
Perform necessary cleaning.
Reading the Results:
Color Explanation
Green The nozzles are not clogged.
Yellow Clogging is detected.
Perform Auto Cleaning (0311) again.
Red Clogging is detected.
Perform Detect Clogging from Nozzle Check (0312), and then perform Powerful cleaning
again for heads indicated by red.
White Auto Cleaning is still in progress.