Administrator's Guide

Settings/Maintenance
62
Problems with Gray Adjustment
Symptom Error Messages What to do
The print quality for the
adjustment pattern is too
low.
-
Is the print head clogged?
Print an adjustment pattern again after performing head
cleaning.
An error occurred while
applying the parameters.
"Try again after closing the
Settings/Maintenance
screen."
"Operation failed."
Are the PC and the printer connected to the spectrometer
correctly?
Check the connection between the PC and the printer, and then
click Apply again.
Is there enough free space on the PC's hard disk?
Make sure there is sufficient free space on the PC's hard disk, and
then click Apply again.
Errors in the adjustments
have been applied. I want
to make adjustments
again.
-
Initialize and then readjust.
Press Clear for the Color Balance, Density Adjustment, and
Gradation Correction to initialize the settings, and then make
adjustments again.
The adjustment values
have been initialized.
-
Have adjustment values been initialized after performing
color calibration?
Perform gray adjustment again.