Network Card User's Manual

3-3
Tighten terminal screws on the power supply terminal block of the display unit with the following torque.
Use a power supply cable within the range shown below.
Types
Tterminal screw
Power
Cable
Screw
size
Tightening
torque
Crimp-style terminal
NP5M0101-5H4
NP5M0101-4H4
NP5N0011-5H4
NP5N0011-4H4
M3.5 0.8N·m AWG18 - 16
NP5M0101-3H4
NP5N0011-3H4
M3.5 1.2N·m AWG16 - 14
The power supply terminal block of the controller unit uses M3 terminal screws. Their tightening torque should be
0.5 to 0.6 N·m.
Select the appropriate cable, and crimp terminals to be used. Applicable cable sizes and crimp terminals are as
follows:
Maker Form Types
Cable size
AWG mm
2
AMP
Round
terminals
36467
22 to 18 0.3 to 0.8 mm
2
34104
34105
Nichifu
Round
terminals
0.3-3
24 to 20 0.2 to 0.5 mm
2
0.3-3N
1.25-3
22 to 16 0.3 to 1.3 mm
2
1.25-3N
1.25-3S
1.25-3.5N
1.25-3.5S
2-3N 16 to 14 1.3 to 2.0 mm
2
Angle edge
terminals
0.3Y-3 24 to 20 0.2 to 0.5 mm
2
1.25Y-3
22 to 16 0.3 to 1.3 mm
2
1.25Y-3N
1.25Y-3S
1.25Y-3.5
2Y-3
16 to 14 1.3 to 2.0 mm
2
2Y-3.5S
AT1-10 22 to 16 0.3 to 1.3 mm
2
AT2-10 16 to 14 1.3 to 2.0 mm
2
JST
Round
terminals
SRA-20-3.2
22 to 18 0.3 to 0.8 mm
2
SRA-20T-3.2
NTK
Round
terminals
0.4-3 26 to 22 0.2 to 0.3 mm
2
1.25-3
22 to 16 0.3 to 1.3 mm
2
Angle edge
terminals
VR1.25-3
VD1.25-3
VD2-3S 16 to 14 1.3 to 2.0 mm
2
7.6
6
Terminal dimensions
3-2 Power Supply Cable Wiring
φ 3.7mm
8mm
or less
3.7mm
8mm
or less
3.7mm
7.1mm
or less
φ 3.7mm
7.1mm
or less