User manual

P07303-II Series Customer Display User's Manual
7.3. UTC Standard Mode Command List
Command Code (hex) Function Description
BS 08 Back space
HT 09 Horizontal tab
LF 0A Line feed
CR 0D Carriage return
DLE n 10 n
Display position
n = 0 ~ 27h, for location.
DC1 11 Over write display mode
DC2 12 Vertical scroll mode
DC3 13 Cursor on
DC4 14 Cursor off
US 1F Clear display
ESC d 1B 64 Change to UTC enhanced mode
7.4. UTC Enhanced Mode Command List
Command Code (hex) Function Description
ESC u A [DATA]
CR
1B 75 41 [DATA] 0D
Upper line display
Maximal [DATA] length is 20
ESC u B [DATA]
CR
1B 75 42 [DATA] 0D
Bottom line display
Maximal [DATA] length is 20
ESC u D [DATA]
CR
1B 75 44 [DATA] 0D
Upper line message scroll continuously
Maximal [DATA] length is 40
ESC u E h h : m
m CR
1B 75 45 h h ':' m m 0D
Display time
h, m = '0' ~ '9'
ESC u F [DATA]
CR
1B 75 46 [DATA] 0D
Upper line message scroll Once pass
Maximal [DATA] length is 40
ESC u H n m CR 1B 75 48 n m 0D
Change attention code
n = 1 ~ 20h
m = 1 ~ 20h
ESC u I [DATA]
CR
1B 75 49 [DATA] 0D
Two line display
Maximal [DATA] length is 40
ESC RS CR 1B 0F 0D Change to UTC standard mode